Oncentra® Brachy Planning System
The creation of the Oncentra Brachy system is another stage in the evolution of radiation therapy planning technologies. Rich experience in creating innovative planning technologies from the first NPS solution to the famous PLATO platform, which became a kind of quality standard in brachytherapy planning, is fully embodied in the Oncentra Brachy system, equipped with the latest volume-based image planning function.
Oncentra Brachy is a comprehensive radiation therapy planning system with a user-friendly interface, equipped with the most modern dose optimization algorithms. Creating highly conformal therapy plans within an efficient workflow is now quite accessible. Oncentra Brachy provides you with the latest tools to help create the most effective brachytherapy plan.
Three-Dimensional Contouring
The Oncentra Brachy system allows you to freely navigate within the image set regardless of the acquisition method (CT, PET/CT, ultrasound, or MRI), easily scroll through images in any plane (sagittal, axial, and arbitrary), which gives complete freedom of action when drawing contours of study areas. The combination of arbitrary plane display capability with other tools, such as the smooth contour drawing tool, allows real-time three-dimensional contouring. This same free navigation function in arbitrary planes is used in catheter reconstruction mode, which makes it possible to view the entire image data set related to a specific applicator position. This easy-to-use function provides fast and very accurate reconstruction, as well as more accurate radiation dose distribution.
- CT/MR image fusion
- Arbitrary plane navigation
- Smooth contour drawing tool
- Three-dimensional boundary definition
- Modern visualization tools
- Study area catalog manager
Reconstruction
Implant and applicator modeling.
The Oncentra Brachy system is equipped with a new implant modeling tool that allows instant reconstruction of implants with multiple catheters. The function of transferring three-dimensional geometric parameters of the applicator to image sets provides fast and accurate reconstruction. Using an additional coordinate system (ECS), you can navigate to the corresponding planar projections and move preset applicator points on them to align with the image set reference points. After placing the applicator, its position can be adjusted if necessary. These functions save significant time since reconstructed implants can be reused.
Dosimetry Optimization
Automatic dose optimization
When planning radiation therapy, it is necessary to simultaneously determine optimal target coverage, ensure uniform dose distribution, and protect organs at risk. The Oncentra Brachy system contains two inverse optimization algorithms that allow automatic calculation of optimal radiation dose distribution taking into account clinical constraints set by the user. At the same time, the user retains full control over automated processes. You can set constraints yourself, as well as combine inverse optimization with any planning and optimization method, for example, with manual source dwell time changes or graphical optimization. This allows you to calculate optimal dose distribution much faster and reduce the number of complex operations for its adjustment.
HIPO and IPSA modules include tools that provide additional optimization of radiation therapy plans.
IPSA module is equipped with a dwell time deviation constant (DTDC) function that allows creating reliable and justified radiation therapy plans by limiting significant deviations in source dwell time values.
HIPO module optimizes radiation therapy plans using the dwell time gradient restriction (DTGR) parameter, which controls significant deviations in source dwell time values in either direction, as well as needle fixation, which allows blocking part of the implant that does not require further optimization and focusing on the area where additional actions are needed, for example, inserting additional brachytherapy needles.
Advanced Collapsed Cone Engine (ACE) Dose Calculation
The Oncentra® Brachy system, equipped with the new Advanced Collapsed Cone Engine (ACE) dose calculation tool, is another step on the path of innovative medical technology development. This brachytherapy dose calculation algorithm is based on TG-186 recommendations published in 2012 by the American Association of Physicists in Medicine (AAPM) task group.
The ACE tool, fully integrated with the Oncentra Brachy system, can differentiate tissues, air, and bone tissue and take into account factors such as tissue heterogeneity, lack of backscatter in areas where there are no tissues, as well as applicator attenuation and shielding. In terms of accuracy, the ACE algorithm is comparable to the Monte Carlo method, but its use speeds up calculations and provides a more accurate picture of actual dose distribution compared to the TG-43 calculation method, which ultimately leads to more informed decisions when prescribing radiation therapy.
Plan Evaluation
Includes evaluation by various criteria, in various combinations
- Real-time dose-volume histogram
- Synchronized plan evaluation
- Dose-volume histogram presets
- Image and volume parameter-based planning
- 2D and 3D visualization